C-10 EX (IT-40L) CFE HEPA:
C-10 EX (IT-40L) CFE HEPA
Information:

CE EX II 3 D Ex h tc IIIC T200°C (T85°C for BLSD version) Dc IP6X

LCIE 19 ATEX 1001 X

IECEx 3rd Party Certified Ex h tc IIIC T200°C (T85°C for BLSD version) Dc IP6X IECEx LCIE 15.0048

ESD Safe Vacuum Systems for Hazardous Locations are designed to prevent ignition hazards.

We use metal parts or Static Dissipative Powder Coating to prevent Electrostatic Discharge (ESD)

  • Legally certified dust ignition protected by an OSHA approved Nationally Recognized Testing Laboratory (NRTL)
  • Immersion separator "Wet Mix". For use with water (no oil)
  • Designed for the recovery and INERTIZATION of combustible dust into a liquid immersion bath
  • Meets the requirements for a Liquid Precipitation Collector for metal dusts as outlined in NFPA 484
  • Electric
  • Coalescing Filter Element (CFE) for moisture removal. HEPA Grade. 99.97% efficiency at 0.3 micron
  • Heavy duty 2-stage by-pass motor
  • Longer life brushless motor available. Always with 4 x H14 HEPA filters
  • Recovery tank made of stainless steel SAE Type 304
  • Disposable collection bag (conductive) - included
  • Recovery capacity - 3.25 gal. (12.3L) of water is required in the recovery tank. The conductive "wet" recovery bag has a recovery capacity of 3L (0.8 gal)
  • Degassing vent allows gas to be evacuated automatically from the unit
  • Equipped with a liquid level indicator
  • Includes a complete static dissipative tool kit

If you need assistance with any of our products please get in touch.

We are always happy to discuss your requirements.